LB Underground Service Locations & Engineering

Induction method is used when we do not have an option to directly connect onto an asset, IE: Limited or no access.

We achieve this by placing the transmitter on the ground and send an electromagnetic signal into the ground to latch onto our assets, this will only work with conductive materials.

There are limitations to this method and that is if there are numerous metallic assets in a very close vicinity. It is very hard to determine between what asset the signal has latched onto.